Hitachi Cooling & Heating / SERIES OVERVIEW

Hitachi WZP / WZX Series

Water-cooled twin-screw chiller

Brand
Hitachi Cooling & Heating
Series
WZP / WZX
Equipment category
Chillers
Request Technical Information
Hitachi WZP / WZX water-cooled twin-screw chiller series reference image
Representative image. Appearance may vary by configuration.

Product overview

WZP and WZX are R134a water-cooled twin-screw chiller selections in the reviewed brochure. Each model retains its own capacity, input power, COP, dimensions and weight. They are distinct from the inverter-driven WV / WVP family.

Key technical specifications

Manufacturer catalog: Hitachi WZP / WZX · Edition: Z0050012-260920 · Reference PDF pages: 6.

WZP: RCUF R134a references

Water-cooled twin-screw WZP models; no inverter drive is inferred. The similarly sized 150/156, 200/211 and later references have distinct input, dimensions and weight.

WZP: RCUF R134a references. Water-cooled twin-screw WZP models; no inverter drive is inferred. The similarly sized 150/156, 200/211 and later references have distinct input, dimensions and weight.
Model referenceCooling capacity(kW)Cooling capacity (source)(RT)Cooling input power(kW)Cooling COP(W/W)Main power supplyRefrigerantCompressor typeLength(mm)Width(mm)Height(mm)Net weight(kg)
RCUF50WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)19054.0432.235.895380 V / 3 phase / 50 HzR134aTwin-screw2200135016001800
RCUF65WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)23867.6940.375.895380 V / 3 phase / 50 HzR134aTwin-screw2200135016001880
RCUF80WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)29884.7650.55.901380 V / 3 phase / 50 HzR134aTwin-screw4000136016003290
RCUF110WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)383108.966.155.79380 V / 3 phase / 50 HzR134aTwin-screw4000136016003450
RCUF130WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)478135.982.565.79380 V / 3 phase / 50 HzR134aTwin-screw4000136016003630
RCUF150WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)549156.188.666.192380 V / 3 phase / 50 HzR134aTwin-screw3373171523114070
RCUF156WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)549156.193.115.896380 V / 3 phase / 50 HzR134aTwin-screw3320170022583540
RCUF200WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)732208.2118.36.188380 V / 3 phase / 50 HzR134aTwin-screw3373171523114400
RCUF211WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)732208.2124.75.87380 V / 3 phase / 50 HzR134aTwin-screw3320170022583820
RCUF250WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)915260.2147.86.191380 V / 3 phase / 50 HzR134aTwin-screw3373171523114680
RCUF261WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)915260.2155.65.88380 V / 3 phase / 50 HzR134aTwin-screw3320170022584040
RCUF300WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)1098312.3174.66.289380 V / 3 phase / 50 HzR134aTwin-screw4804194924198560
RCUF311WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)1098312.3183.35.99380 V / 3 phase / 50 HzR134aTwin-screw4672176623196650
RCUF366WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)1281364.3211.46.06380 V / 3 phase / 50 HzR134aTwin-screw4672176623196950
RCUF421WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)1464416.4240.86.08380 V / 3 phase / 50 HzR134aTwin-screw4672176623197250
RCUF471WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)1647468.4271.36.071380 V / 3 phase / 50 HzR134aTwin-screw4672176623197500
RCUF521WZPRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)1830520.5300.56.09380 V / 3 phase / 50 HzR134aTwin-screw4672176623197750
  • Cooling rating: chilled-water leaving temperature 7 °C; condenser-water entering temperature 30 °C; chilled/condenser-water flow rates 0.172 / 0.215 m³/(h·kW). These are the stated selection conditions, not a generic 12/7 °C rating.
  • RT and kW are copied independently from the source, not converted. COP is the stated rating under the table's selection conditions.
  • Main supply: 380 V / 3 phase / 50 Hz; control supply: 220 V / 1 phase / 50 Hz. Chilled-water leaving range: 5–20 °C for RCUF50–130WZP; 4–15 °C for RCUF150–521WZP. Condenser-water leaving: 22–40 °C.
  • Brochure reference ratings are not a current stock or delivery guarantee. Confirm the complete configuration, nameplate, destination-market requirements and current selection before procurement.

WZX: RCUF R134a references

WZX is kept separate from WZP; its capacity, input, COP and net weight must not be replaced by WZP values.

WZX: RCUF R134a references. WZX is kept separate from WZP; its capacity, input, COP and net weight must not be replaced by WZP values.
Model referenceCooling capacity(kW)Cooling capacity (source)(RT)Cooling input power(kW)Cooling COP(W/W)Main power supplyRefrigerantCompressor typeLength(mm)Width(mm)Height(mm)Net weight(kg)
RCUF80WZXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)30787.3150.716.054380 V / 3 phase / 50 HzR134aTwin-screw4000136016003300
RCUF110WZXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)395112.365.266.052380 V / 3 phase / 50 HzR134aTwin-screw4000136016003480
RCUF130WZXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab)492139.981.286.053380 V / 3 phase / 50 HzR134aTwin-screw4000136016003660
  • Cooling rating: chilled-water leaving temperature 7 °C; condenser-water entering temperature 30 °C; chilled/condenser-water flow rates 0.172 / 0.215 m³/(h·kW). These are the stated selection conditions, not a generic 12/7 °C rating.
  • RT and kW are the brochure's independently printed values. Main supply: 380 V / 3 phase / 50 Hz; control: 220 V / 1 phase / 50 Hz. Chilled-water leaving 5–20 °C; condenser-water leaving 22–40 °C.
  • Brochure reference ratings are not a current stock or delivery guarantee. Confirm the complete configuration, nameplate, destination-market requirements and current selection before procurement.

Key configuration options

  • WZP and WZX are separate technical selections; similar size codes do not mean identical ratings.
  • Condenser-water conditions, pressure rating, heat recovery and water-box options require project selection.

Applications

  • Central chilled-water plants with condenser-water systems
  • Project-specific water-cooled equipment supply

Information for equipment selection

  • Complete model / configuration and equipment schedule
  • Required duty and design water / ambient conditions
  • Power supply, installation space and project location
  • Destination-market requirements and current availability confirmation

Technical Documents

Request Technical Information

Related series

REQUEST A QUOTE / TECHNICAL INFORMATION

Discuss your project equipment

Product reference: Hitachi WZP / WZX Series

Send your BOQ or equipment schedule, cooling/heating capacity, application, project location, design requirements, power supply and expected procurement timeline. Installation, commissioning and after-sales arrangements can be included where expressly agreed for the project.

Email your requirements to [email protected]. You can include your BOQ or equipment schedule. See what to include in your inquiry.