Hitachi Cooling & Heating · Series overview
Hitachi WV / WVP Series
Water-cooled inverter screw chiller
Hitachi Cooling & Heating / SERIES OVERVIEW
Air-cooled inverter screw chiller / heat pump

AVX uses R134a and inverter-driven semi-hermetic twin-screw compressors. Cooling-only RCUF and heat-pump RHUF ratings are kept in separate tables. Standard, all-year and heat-recovery selections require confirmation of the complete model and design conditions.
Manufacturer catalog: Hitachi AVX · Edition: Z0050068-260807 · Reference PDF pages: 6.
Start with the required cooling or heating duty, water temperatures and outdoor conditions. Compare each model at the table's stated test conditions, then confirm the power supply and configuration for your project. The listed 50 Hz ratings do not establish 60 Hz suitability.
Standard AVX references; N all-year and heat-recovery variants require their own selection. The model codes combine the printed prefix, size and AVX suffix from the nomenclature.
| Model reference | Cooling capacity(kW) | Cooling input power(kW) | Cooling COP(W/W) | Main power supply | Refrigerant | Compressor type | Length(mm) | Width(mm) | Height(mm) | Net weight(kg) |
|---|---|---|---|---|---|---|---|---|---|---|
| RCUF150AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 502 | 154 | 3.26 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 6300 | 2052 | 2456 | 5450 |
| RCUF180AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 620 | 193.8 | 3.199 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 6300 | 2052 | 2456 | 5960 |
| RCUF200AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 669 | 209.1 | 3.199 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 6300 | 2052 | 2456 | 6050 |
| RCUF300AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1004 | 308 | 3.26 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 12700 | 2052 | 2456 | 10900 |
| RCUF330AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1122 | 347.8 | 3.226 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 12700 | 2052 | 2456 | 11410 |
| RCUF350AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1171 | 363.1 | 3.225 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 12700 | 2052 | 2456 | 11500 |
| RCUF380AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1289 | 402.9 | 3.199 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 12700 | 2052 | 2456 | 12010 |
| RCUF400AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1338 | 418.2 | 3.199 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 12700 | 2052 | 2456 | 12100 |
| RCUF450AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1506 | 462 | 3.26 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 19100 | 2052 | 2456 | 16350 |
| RCUF500AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1673 | 517.1 | 3.235 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 19100 | 2052 | 2456 | 16950 |
| RCUF550AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1840 | 572.2 | 3.216 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 19100 | 2052 | 2456 | 17550 |
| RCUF600AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 2007 | 627.3 | 3.199 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 19100 | 2052 | 2456 | 18150 |
Standard AVX references; N all-year and heat-recovery variants require their own selection. The model codes combine the printed prefix, size and AVX suffix from the nomenclature.
| Model reference | Cooling capacity(kW) | Cooling input power(kW) | Cooling COP(W/W) | Heating capacity(kW) | Heating input power(kW) | Heating COP(W/W) | Main power supply | Refrigerant | Compressor type | Length(mm) | Width(mm) | Height(mm) | Net weight(kg) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RHUF150AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 502 | 154 | 3.26 | 488 | 148.8 | 3.28 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 6300 | 2052 | 2456 | 6000 |
| RHUF180AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 620 | 193.8 | 3.199 | 588 | 186.5 | 3.153 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 6300 | 2052 | 2456 | 6510 |
| RHUF200AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 669 | 209.1 | 3.199 | 650 | 200.9 | 3.235 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 6300 | 2052 | 2456 | 6600 |
| RHUF300AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1004 | 308 | 3.26 | 976 | 297.6 | 3.28 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 12700 | 2052 | 2456 | 12000 |
| RHUF330AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1122 | 347.8 | 3.226 | 1076 | 335.3 | 3.209 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 12700 | 2052 | 2456 | 12510 |
| RHUF350AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1171 | 363.1 | 3.225 | 1138 | 349.7 | 3.254 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 12700 | 2052 | 2456 | 12600 |
| RHUF380AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1289 | 402.9 | 3.199 | 1238 | 387.4 | 3.196 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 12700 | 2052 | 2456 | 13110 |
| RHUF400AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1338 | 418.2 | 3.199 | 1300 | 401.8 | 3.235 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 12700 | 2052 | 2456 | 13200 |
| RHUF450AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1506 | 462 | 3.26 | 1464 | 446.3 | 3.28 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 19100 | 2052 | 2456 | 18000 |
| RHUF500AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1673 | 517.1 | 3.235 | 1626 | 498.5 | 3.262 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 19100 | 2052 | 2456 | 18600 |
| RHUF550AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 1840 | 572.2 | 3.216 | 1788 | 550.6 | 3.247 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 19100 | 2052 | 2456 | 19200 |
| RHUF600AVXRequest a QuoteDiscuss This Model (opens WhatsApp in a new tab) | 2007 | 627.3 | 3.199 | 1950 | 602.7 | 3.235 | 380 V or 415 V / 3 phase / 50 Hz (confirm selection) | R134a | Semi-hermetic twin-screw, inverter driven | 19100 | 2052 | 2456 | 19800 |
Send these details with your inquiry so we can review the selected model, destination requirements and supply options.

Hitachi Cooling & Heating · Series overview
Water-cooled inverter screw chiller

Hitachi Cooling & Heating · Series overview
Air-Cooled Scroll Chiller / Heat Pump
REQUEST A QUOTE / TECHNICAL INFORMATION
Product reference: Hitachi AVX Series
Send your BOQ or equipment schedule, cooling/heating capacity, application, project location, design requirements, power supply and expected procurement timeline. Installation, commissioning and after-sales arrangements can be included where expressly agreed for the project.
Email your requirements to [email protected]. You can include your BOQ or equipment schedule. See what to include in your inquiry.