YORK / SERIES OVERVIEW

YORK YAFC Series

Residential hydronic indoor unit with air-treatment options

Brand
YORK
Series
YAFC
Equipment category
Fan Coil Units

Availability on Request · Existing inventory

Check Availability
YORK YAFC residential concealed fan coil series reference image

Product overview

YAFC is a YORK residential concealed indoor-unit series with hydronic cooling / heating and air-treatment configuration options. The reviewed H (30 Pa) table is kept separate from U (50 Pa) ratings. No filtration effectiveness, health benefit or certification is claimed here.

BUYING FROM EXISTING INVENTORY

Wholesale Purchasing Information

New, unused YORK equipment, originally supplied in factory packaging. Based on our current inventory records, most YORK main units are from 2022 or later production batches. The manufacturing date and condition of each offered unit will be verified before order acceptance.

  1. Identify the equipmentSend the full model, quantity, destination, power supply and required configuration.
  2. Review a batch-specific offerReview equipment condition, available quantity, agreed pre-shipment checks and model-specific electrical/configuration suitability.
  3. Agree the order termsThe formal quotation records the equipment, pricing, shipment scope, delivery arrangements and applicable warranty/claims terms.

Configuration and support before ordering

Certain main units may be opened for regional configuration by Delta M&E personnel and repacked before shipment. Feasibility is checked by exact model; this is not a claim of manufacturer authorization. Factory-sealed condition and manufacturer warranty must not be assumed after adjustment.

Smart Panel functionality is not supported on affected units after regional configuration. Future availability or restoration is not guaranteed and must not be relied upon as a purchasing assumption. This concerns IWE Smart Panel, not every thermostat, controller or app.

Operating functions, controller compatibility and connectivity must be verified for the exact model and system configuration. Only functions expressly confirmed in the relevant quotation or technical records should be relied upon.

Overseas installation, on-site commissioning and routine local after-sales service are not included by default. Verified seller-responsible defects remain eligible for appropriate remedies. Relevant limitations and buyer acknowledgments are recorded in the actual quotation or sales agreement before order acceptance.

Inventory model references

Key technical specifications

Manufacturer catalog: YORK YAFC · Edition: PUBL-5487ZH (0621) · Reference PDF pages: 3–4.

YAFC: CD, 3-row, H (30 Pa) references

High fan speed; reviewed 2021 high-static-pressure table. The full A / B design-version stock codes are listed separately; the table is not confirmation of every stock unit's configuration.

YAFC: CD, 3-row, H (30 Pa) references. High fan speed; reviewed 2021 high-static-pressure table. The full A / B design-version stock codes are listed separately; the table is not confirmation of every stock unit's configuration.
Model referenceExternal static pressure(Pa)Airflow (high speed)(m³/h)Total cooling capacity(kW)Heating capacity(kW)Voltage(V)Frequency(Hz)
YAFC02CD3H303402.453.822050
YAFC03CD3H305203.455.4622050
YAFC04CD3H306804.226.9822050
YAFC05CD3H308505.168.122050
YAFC06CD3H3010206.410.1322050
YAFC07CD3H3011706.6810.8322050
YAFC08CD3H3013608.513.1822050
YAFC10CD3H3017109.115.9622050
  • Cooling rating: return air 27 °C dry bulb / 19.5 °C wet bulb; entering water 7 °C; water temperature rise 5 °C; high fan speed.
  • Heating rating: return air 21 °C dry bulb; entering water 60 °C; high fan speed.
  • Brochure ratings were tested at 220 V / 50 Hz without a return box. Fan airflow was measured without the electrostatic module; the brochure supplies separate airflow correction factors for that module. Do not assume the uncorrected airflow for an equipped unit.
  • U = 50 Pa has a separate table and must not use the H ratings. Complete design-version A / B and accessory selections require review.
  • Brochure ratings apply only to the listed model references and configuration. Confirm the complete model code, nameplate and current technical selection before procurement. They do not establish stock, export suitability or lead time.

Key configuration options

  • Confirm the return-box, electrostatic module, filter, drain pan and connection side from the complete code.
  • Stock includes A / B suffix references; the supplied 2021 nomenclature does not establish equivalence between those design versions.

Applications

  • Residential room cooling and heating
  • Concealed ceiling installation with a hydronic system

Information for equipment selection

  • Complete model code and required configuration
  • Cooling / heating duty and design water / air conditions
  • Electrical supply, quantity and project location
  • Installation arrangement and availability requirements

Technical Documents

Request Technical Information

Related series

REQUEST A QUOTE / TECHNICAL INFORMATION

Request a model-specific wholesale offer

Product reference: YORK YAFC Series

Send the full model, quantity and destination. We will review the offered unit, configuration and agreed delivery scope for your formal quotation.

Review Warranty & After-Sales Support and Returns & Claims before ordering.

Email your requirements to [email protected]. You can include your BOQ or equipment schedule. See what to include in your inquiry.