YORK / SERIES OVERVIEW

YORK YCRU-K / YCRU-B Series

Kitchen / bathroom hydronic indoor-unit family

Brand
YORK
Series
YCRU-K / YCRU-B
Equipment category
Fan Coil Units

Availability on Request · Existing inventory

Check Availability
YORK YCRU-K kitchen indoor unit with separate panel reference image
YCRU-K kitchen-unit illustration. YCRU-B bathroom-unit appearance and technical data await matching documentation.

Product overview

The reviewed YCRU nomenclature identifies K as the kitchen application and B as the bathroom application. Kitchen-unit K032E ratings are shown below. YCRU-B stock references are listed for availability inquiry only: no bathroom-unit capacity is inferred from the K table.

BUYING FROM EXISTING INVENTORY

Wholesale Purchasing Information

New, unused YORK equipment, originally supplied in factory packaging. Based on our current inventory records, most YORK main units are from 2022 or later production batches. The manufacturing date and condition of each offered unit will be verified before order acceptance.

  1. Identify the equipmentSend the full model, quantity, destination, power supply and required configuration.
  2. Review a batch-specific offerReview equipment condition, available quantity, agreed pre-shipment checks and model-specific electrical/configuration suitability.
  3. Agree the order termsThe formal quotation records the equipment, pricing, shipment scope, delivery arrangements and applicable warranty/claims terms.

Configuration and support before ordering

Certain main units may be opened for regional configuration by Delta M&E personnel and repacked before shipment. Feasibility is checked by exact model; this is not a claim of manufacturer authorization. Factory-sealed condition and manufacturer warranty must not be assumed after adjustment.

Smart Panel functionality is not supported on affected units after regional configuration. Future availability or restoration is not guaranteed and must not be relied upon as a purchasing assumption. This concerns IWE Smart Panel, not every thermostat, controller or app.

Operating functions, controller compatibility and connectivity must be verified for the exact model and system configuration. Only functions expressly confirmed in the relevant quotation or technical records should be relied upon.

Overseas installation, on-site commissioning and routine local after-sales service are not included by default. Verified seller-responsible defects remain eligible for appropriate remedies. Relevant limitations and buyer acknowledgments are recorded in the actual quotation or sales agreement before order acceptance.

Inventory model references

Key technical specifications

Manufacturer catalog: YORK YCRU-K · Edition: PUBL-7067ZH (0624) · Reference PDF pages: 4, 6–7.

YCRU-K032E: kitchen-unit reference only

The reviewed kitchen brochure contains this K032E reference at 0 Pa external static pressure. These values must not be applied to YCRU-B bathroom units or SP panel/accessory codes.

YCRU-K032E: kitchen-unit reference only. The reviewed kitchen brochure contains this K032E reference at 0 Pa external static pressure. These values must not be applied to YCRU-B bathroom units or SP panel/accessory codes.
Model referenceExternal static pressure(Pa)Rated airflow(m³/h)Total cooling capacity(kW)Heating capacity(kW)Heating (45 °C water)(kW)Voltage(V)Frequency(Hz)
YCRU-K032E05103.253.122050
  • Cooling: return air 27 °C dry bulb / 19.5 °C wet bulb; entering water 7 °C; water temperature rise 5 °C.
  • Heating: return air 21 °C dry bulb; entering water 60 °C or 45 °C respectively, at the cooling-rating water flow.
  • Airflow: standard air, dry coil, entering air 20 °C; tested at 220 V / 50 Hz, 0 Pa. The source explicitly specifies a 0 Pa rating.
  • The K nomenclature has 2-pipe selection, E = 0–10 V EC motor and optional N air-treatment kit. YCRU-B capacity / electrical configuration requires its own documentation.
  • Brochure ratings apply only to the listed model references and configuration. Confirm the complete model code, nameplate and current technical selection before procurement. They do not establish stock, export suitability or lead time.

Key configuration options

  • K and B are application variants, not interchangeable model ratings.
  • SP codes identify separate panel configurations in the reviewed nomenclature, not complete indoor units.
  • Confirm the body, panel, air-treatment kit and left / right arrangement before ordering.

Applications

  • Kitchen room cooling / heating with a hydronic system (K application)
  • Bathroom application variant (B); technical selection requires its own documentation

Information for equipment selection

  • Complete model code and required configuration
  • Cooling / heating duty and design water / air conditions
  • Electrical supply, quantity and project location
  • Installation arrangement and availability requirements

Technical Documents

Request Technical Information

Related series

REQUEST A QUOTE / TECHNICAL INFORMATION

Request a model-specific wholesale offer

Product reference: YORK YCRU-K / YCRU-B Series

Send the full model, quantity and destination. We will review the offered unit, configuration and agreed delivery scope for your formal quotation.

Review Warranty & After-Sales Support and Returns & Claims before ordering.

Email your requirements to [email protected]. You can include your BOQ or equipment schedule. See what to include in your inquiry.