Hitachi Cooling & Heating / SERIES OVERVIEW

Hitachi VG Direct-Drive Inverter Centrifugal Chillers

Water-cooled, oil-lubricated direct-drive inverter centrifugal chiller

Brand
Hitachi Cooling & Heating
Series
VG
Equipment category
Chillers

Product overview

VG combines a direct-drive centrifugal compressor with inverter control and an oil-lubricated bearing system. D references use an asynchronous motor; M references use a permanent-magnet motor. GXVG and GFVG selections have separate performance and heat-exchanger data. The four R134a tables cover 34 complete examples from 350 to 1,100 USRT; VG is a different technical route from magnetic-bearing VM equipment.

Key technical specifications

Match the complete model and configuration to your design duty. Compare ratings only at the stated water and ambient conditions; then send the model reference, quantity and project requirements for review.

Scroll each table horizontally to compare all columns. Model references remain visible as you scroll.

VG D asynchronous motor / GXVG — cooling performance

VG D asynchronous motor / GXVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.

VG D asynchronous motor / GXVG — cooling performance. VG D asynchronous motor / GXVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.
Model referenceCooling capacity (source)(USRT)Cooling capacity(kW)Cooling input power(kW)Full-load input / ton(kW/TR)Cooling COP(W/W)IPLV.SI(W/W)Rated current(A)
HC-F10D-L30EB06SCB04-GXVG-SCRequest a Quote3501231216.90.625.6739.668358
HC-F10D-L30EB05SCB08-GXVG-SCRequest a Quote4501582278.40.6195.6839.687460
HC-F20D-L30EC09SCC01-GXVG-SCRequest a Quote5501934337.50.6145.739.764557
HC-F20D-L30EC11SCC07-GXVG-SCRequest a Quote6502286398.50.6135.7359.77658
HC-F25D-L30ED10SCE09-GXVG-SCRequest a Quote7502637465.20.625.6699.662768
HC-F25D-L30ED03SCE07-GXVG-SCRequest a Quote8502989525.50.6185.6889.692868
HC-F30D-L30EE04SCM08-GXVG-SCRequest a Quote9503340586.40.6175.6979.708968
HC-F30D-L30EE03SCM04-GXVG-SCRequest a Quote10503692646.90.6165.7079.7251068
  • Cooling rating: chilled water entering / leaving 12 / 7 °C; condenser water entering / leaving 32 / 37 °C. Water-side fouling factors: evaporator 0.018 m²·°C/kW; condenser 0.044 m²·°C/kW. Capacities in USRT and kW, input power, COP and kW/TR are the independently printed values, not recalculated conversions. IPLV.SI, where listed, is a separate part-load index.
  • Main supply: 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a references only. Net and operating weights remain in the source unit t (tonnes).
  • These are manufacturer selection examples. Confirm the full model, water conditions, electrical configuration, plant-room access and destination requirements for the equipment quotation.

VG D asynchronous motor / GXVG — water-side and installation data

VG D asynchronous motor / GXVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.

VG D asynchronous motor / GXVG — water-side and installation data. VG D asynchronous motor / GXVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.
Model referenceEvaporator water flow(m³/h)Evaporator pressure drop(kPa)Evaporator connectionCondenser water flow(m³/h)Condenser pressure drop(kPa)Condenser connectionLength(mm)Width(mm)Height(mm)Net weight(t)Operating weight(t)
HC-F10D-L30EB06SCB04-GXVG-SCRequest a Quote211.760DN200248.353.8DN2003650185023005.87
HC-F10D-L30EB05SCB08-GXVG-SCRequest a Quote272.260DN200319.156.7DN2003650185023005.97.2
HC-F20D-L30EC09SCC01-GXVG-SCRequest a Quote332.660DN200389.658.3DN2503650195024507.49
HC-F20D-L30EC11SCC07-GXVG-SCRequest a Quote393.160.7DN250460.358DN2503650195024507.59.2
HC-F25D-L30ED10SCE09-GXVG-SCRequest a Quote453.661.4DN25053260DN2503700245028509.611.5
HC-F25D-L30ED03SCE07-GXVG-SCRequest a Quote514.162DN250602.757.5DN3003700245028509.711.7
HC-F30D-L30EE04SCM08-GXVG-SCRequest a Quote574.662.8DN300673.458.4DN30037002500290011.714
HC-F30D-L30EE03SCM04-GXVG-SCRequest a Quote63561.8DN300744.160DN35037002500290011.914.3
  • Cooling rating: chilled water entering / leaving 12 / 7 °C; condenser water entering / leaving 32 / 37 °C. Water-side fouling factors: evaporator 0.018 m²·°C/kW; condenser 0.044 m²·°C/kW. Capacities in USRT and kW, input power, COP and kW/TR are the independently printed values, not recalculated conversions. IPLV.SI, where listed, is a separate part-load index.
  • Main supply: 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a references only. Net and operating weights remain in the source unit t (tonnes).
  • These are manufacturer selection examples. Confirm the full model, water conditions, electrical configuration, plant-room access and destination requirements for the equipment quotation.

VG D asynchronous motor / GFVG — cooling performance

VG D asynchronous motor / GFVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.

VG D asynchronous motor / GFVG — cooling performance. VG D asynchronous motor / GFVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.
Model referenceCooling capacity (source)(USRT)Cooling capacity(kW)Cooling input power(kW)Full-load input / ton(kW/TR)Cooling COP(W/W)IPLV.SI(W/W)Rated current(A)
HC-F10D-L40EB06SCB04-GFVG-SCRequest a Quote3501231205.10.586610.22339
HC-F10D-L40EB05SCB08-GFVG-SCRequest a Quote4501582262.60.5846.02610.27434
HC-F20D-L40EC09SCC01-GFVG-SCRequest a Quote5501934311.60.5676.20710.58515
HC-F20D-L40EC11SCC07-GFVG-SCRequest a Quote6502286367.70.5666.21610.59607
HC-F25D-L40ED10SCE09-GFVG-SCRequest a Quote7502637436.80.5826.03710.29721
HC-F25D-L40ED03SCE07-GFVG-SCRequest a Quote8502989494.30.5826.04710.3816
HC-F30D-L40EE04SCM08-GFVG-SCRequest a Quote9503340550.90.586.06410.33910
HC-F30D-L40EE03SCM04-GFVG-SCRequest a Quote10503692607.90.5796.07410.351004
HC-F30D-L40EE09SCM09-GFVG-SCRequest a Quote11003868635.90.5786.08310.371050
  • Cooling rating: chilled water entering / leaving 12 / 7 °C; condenser water entering / leaving 32 / 37 °C. Water-side fouling factors: evaporator 0.018 m²·°C/kW; condenser 0.044 m²·°C/kW. Capacities in USRT and kW, input power, COP and kW/TR are the independently printed values, not recalculated conversions. IPLV.SI, where listed, is a separate part-load index.
  • Main supply: 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a references only. Net and operating weights remain in the source unit t (tonnes).
  • These are manufacturer selection examples. Confirm the full model, water conditions, electrical configuration, plant-room access and destination requirements for the equipment quotation.

VG D asynchronous motor / GFVG — water-side and installation data

VG D asynchronous motor / GFVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.

VG D asynchronous motor / GFVG — water-side and installation data. VG D asynchronous motor / GFVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.
Model referenceEvaporator water flow(m³/h)Evaporator pressure drop(kPa)Evaporator connectionCondenser water flow(m³/h)Condenser pressure drop(kPa)Condenser connectionLength(mm)Width(mm)Height(mm)Net weight(t)Operating weight(t)
HC-F10D-L40EB06SCB04-GFVG-SCRequest a Quote211.779.5DN200246.364.2DN2004650185023006.47.9
HC-F10D-L40EB05SCB08-GFVG-SCRequest a Quote272.277.9DN200316.467.9DN2004650185023006.58.2
HC-F20D-L40EC09SCC01-GFVG-SCRequest a Quote332.679.7DN200385.269.7DN2504650195024508.110
HC-F20D-L40EC11SCC07-GFVG-SCRequest a Quote393.180.9DN250455.169.3DN2504650195024508.210.3
HC-F25D-L40ED10SCE09-GFVG-SCRequest a Quote453.681.9DN250527.373.3DN25047002450285010.512.8
HC-F25D-L40ED03SCE07-GFVG-SCRequest a Quote514.182.7DN250597.468.9DN30047002450285010.713.2
HC-F30D-L40EE04SCM08-GFVG-SCRequest a Quote574.683.8DN300667.470.1DN30047002500290012.114.9
HC-F30D-L40EE03SCM04-GFVG-SCRequest a Quote63582.4DN300737.572.5DN35047002500290012.415.3
HC-F30D-L40EE09SCM09-GFVG-SCRequest a Quote665.381.8DN300772.571.7DN35047002500290012.515.5
  • Cooling rating: chilled water entering / leaving 12 / 7 °C; condenser water entering / leaving 32 / 37 °C. Water-side fouling factors: evaporator 0.018 m²·°C/kW; condenser 0.044 m²·°C/kW. Capacities in USRT and kW, input power, COP and kW/TR are the independently printed values, not recalculated conversions. IPLV.SI, where listed, is a separate part-load index.
  • Main supply: 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a references only. Net and operating weights remain in the source unit t (tonnes).
  • These are manufacturer selection examples. Confirm the full model, water conditions, electrical configuration, plant-room access and destination requirements for the equipment quotation.

VG M permanent-magnet motor / GXVG — cooling performance

VG M permanent-magnet motor / GXVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.

VG M permanent-magnet motor / GXVG — cooling performance. VG M permanent-magnet motor / GXVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.
Model referenceCooling capacity (source)(USRT)Cooling capacity(kW)Cooling input power(kW)Full-load input / ton(kW/TR)Cooling COP(W/W)IPLV.SI(W/W)Rated current(A)
HC-F10M-L30EB06SCB04-GXVG-SCRequest a Quote3501231216.20.6185.6929.919350
HC-F10M-L30EB05SCB08-GXVG-SCRequest a Quote45015822780.6185.6929.921449
HC-F20M-L30EC09SCC01-GXVG-SCRequest a Quote5501934337.50.6145.7319.99545
HC-F20M-L30EC11SCC07-GXVG-SCRequest a Quote6502286398.70.6135.7339.99644
HC-F25M-L30ED10SCE09-GXVG-SCRequest a Quote7502637463.20.6185.6939.922749
HC-F25M-L30ED03SCE07-GXVG-SCRequest a Quote8502989524.90.6185.6949.924848
HC-F30M-L30EE04SCM08-GXVG-SCRequest a Quote9503340586.40.6175.6979.931948
HC-F30M-L30EE03SCM04-GXVG-SCRequest a Quote10503692647.10.6165.7069.9461046
  • Cooling rating: chilled water entering / leaving 12 / 7 °C; condenser water entering / leaving 32 / 37 °C. Water-side fouling factors: evaporator 0.018 m²·°C/kW; condenser 0.044 m²·°C/kW. Capacities in USRT and kW, input power, COP and kW/TR are the independently printed values, not recalculated conversions. IPLV.SI, where listed, is a separate part-load index.
  • Main supply: 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a references only. Net and operating weights remain in the source unit t (tonnes).
  • These are manufacturer selection examples. Confirm the full model, water conditions, electrical configuration, plant-room access and destination requirements for the equipment quotation.

VG M permanent-magnet motor / GXVG — water-side and installation data

VG M permanent-magnet motor / GXVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.

VG M permanent-magnet motor / GXVG — water-side and installation data. VG M permanent-magnet motor / GXVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.
Model referenceEvaporator water flow(m³/h)Evaporator pressure drop(kPa)Evaporator connectionCondenser water flow(m³/h)Condenser pressure drop(kPa)Condenser connectionLength(mm)Width(mm)Height(mm)Net weight(t)Operating weight(t)
HC-F10M-L30EB06SCB04-GXVG-SCRequest a Quote211.760DN200248.353.8DN2003650185023005.87
HC-F10M-L30EB05SCB08-GXVG-SCRequest a Quote272.260DN200319.156.7DN2003650185023005.97.2
HC-F20M-L30EC09SCC01-GXVG-SCRequest a Quote332.660DN200389.658.3DN2503650195024507.49
HC-F20M-L30EC11SCC07-GXVG-SCRequest a Quote393.160.7DN250460.358DN2503650195024507.59.2
HC-F25M-L30ED10SCE09-GXVG-SCRequest a Quote453.661.4DN25053260DN2503700245028509.611.5
HC-F25M-L30ED03SCE07-GXVG-SCRequest a Quote514.162DN250602.757.5DN3003700245028509.711.7
HC-F30M-L30EE04SCM08-GXVG-SCRequest a Quote574.662.8DN300673.458.4DN30037002500290011.714
HC-F30M-L30EE03SCM04-GXVG-SCRequest a Quote63561.8DN300744.160DN35037002500290011.914.3
  • Cooling rating: chilled water entering / leaving 12 / 7 °C; condenser water entering / leaving 32 / 37 °C. Water-side fouling factors: evaporator 0.018 m²·°C/kW; condenser 0.044 m²·°C/kW. Capacities in USRT and kW, input power, COP and kW/TR are the independently printed values, not recalculated conversions. IPLV.SI, where listed, is a separate part-load index.
  • Main supply: 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a references only. Net and operating weights remain in the source unit t (tonnes).
  • These are manufacturer selection examples. Confirm the full model, water conditions, electrical configuration, plant-room access and destination requirements for the equipment quotation.

VG M permanent-magnet motor / GFVG — cooling performance

VG M permanent-magnet motor / GFVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.

VG M permanent-magnet motor / GFVG — cooling performance. VG M permanent-magnet motor / GFVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.
Model referenceCooling capacity (source)(USRT)Cooling capacity(kW)Cooling input power(kW)Full-load input / ton(kW/TR)Cooling COP(W/W)IPLV.SI(W/W)Rated current(A)
HC-F10M-L40EB06SCB04-GFVG-SCRequest a Quote3501231204.10.5836.0310.41330
HC-F10M-L40EB05SCB08-GFVG-SCRequest a Quote4501582262.20.5836.03510.42424
HC-F20M-L40EC09SCC01-GFVG-SCRequest a Quote5501934311.10.5666.21710.74503
HC-F20M-L40EC11SCC07-GFVG-SCRequest a Quote6502286367.10.5656.22610.75593
HC-F25M-L40ED10SCE09-GFVG-SCRequest a Quote7502637435.30.586.05910.46704
HC-F25M-L40ED03SCE07-GFVG-SCRequest a Quote8502989491.90.5796.07610.49795
HC-F30M-L40EE04SCM08-GFVG-SCRequest a Quote9503340548.20.5776.09310.52886
HC-F30M-L40EE03SCM04-GFVG-SCRequest a Quote10503692605.10.5766.10210.54978
HC-F30M-L40EE09SCM09-GFVG-SCRequest a Quote11003868632.80.5756.11210.551023
  • Cooling rating: chilled water entering / leaving 12 / 7 °C; condenser water entering / leaving 32 / 37 °C. Water-side fouling factors: evaporator 0.018 m²·°C/kW; condenser 0.044 m²·°C/kW. Capacities in USRT and kW, input power, COP and kW/TR are the independently printed values, not recalculated conversions. IPLV.SI, where listed, is a separate part-load index.
  • Main supply: 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a references only. Net and operating weights remain in the source unit t (tonnes).
  • These are manufacturer selection examples. Confirm the full model, water conditions, electrical configuration, plant-room access and destination requirements for the equipment quotation.

VG M permanent-magnet motor / GFVG — water-side and installation data

VG M permanent-magnet motor / GFVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.

VG M permanent-magnet motor / GFVG — water-side and installation data. VG M permanent-magnet motor / GFVG. 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a. Each complete reference includes its compressor and heat-exchanger selection.
Model referenceEvaporator water flow(m³/h)Evaporator pressure drop(kPa)Evaporator connectionCondenser water flow(m³/h)Condenser pressure drop(kPa)Condenser connectionLength(mm)Width(mm)Height(mm)Net weight(t)Operating weight(t)
HC-F10M-L40EB06SCB04-GFVG-SCRequest a Quote211.779.5DN200246.164.1DN2004650185023006.47.9
HC-F10M-L40EB05SCB08-GFVG-SCRequest a Quote272.277.9DN200316.467.8DN2004650185023006.58.2
HC-F20M-L40EC09SCC01-GFVG-SCRequest a Quote332.679.7DN200385.169.7DN2504650195024508.110
HC-F20M-L40EC11SCC07-GFVG-SCRequest a Quote393.180.9DN25045569.3DN2504650195024508.210.3
HC-F25M-L40ED10SCE09-GFVG-SCRequest a Quote453.681.9DN25052773.3DN25047002450285010.512.8
HC-F25M-L40ED03SCE07-GFVG-SCRequest a Quote514.182.7DN25059768.8DN30047002450285010.713.2
HC-F30M-L40EE04SCM08-GFVG-SCRequest a Quote574.683.8DN30066770DN30047002500290012.114.9
HC-F30M-L40EE03SCM04-GFVG-SCRequest a Quote63582.4DN300737.172.5DN35047002500290012.415.3
HC-F30M-L40EE09SCM09-GFVG-SCRequest a Quote665.381.8DN30077271.6DN35047002500290012.515.5
  • Cooling rating: chilled water entering / leaving 12 / 7 °C; condenser water entering / leaving 32 / 37 °C. Water-side fouling factors: evaporator 0.018 m²·°C/kW; condenser 0.044 m²·°C/kW. Capacities in USRT and kW, input power, COP and kW/TR are the independently printed values, not recalculated conversions. IPLV.SI, where listed, is a separate part-load index.
  • Main supply: 380 V / 3 phase / 3 wire / 50 Hz; inverter starting. R134a references only. Net and operating weights remain in the source unit t (tonnes).
  • These are manufacturer selection examples. Confirm the full model, water conditions, electrical configuration, plant-room access and destination requirements for the equipment quotation.

Key configuration options

  • Choose D or M motor configuration and GXVG or GFVG heat-exchanger selection before comparing ratings.
  • The listed references use R134a and 380 V / 3 phase / 3 wire / 50 Hz with inverter starting. ZE / R1234ze(E) ratings are not assigned from these F-code tables.
  • Water pressure rating, water-box access, connection direction and control interfaces are project-specific selections.
  • Manufacturer reference: VG brochure, print code Z0050026-251008. A short capacity code alone does not identify the complete selected unit.

Applications

  • Central chilled-water plants for large commercial buildings and manufacturing facilities.
  • Industrial cooling equipment procurement based on the required water temperatures, load and site conditions.

Information for equipment selection

  • Cooling duty, load profile and required quantity; complete model reference where known.
  • Chilled-water and condenser-water entering / leaving temperatures, flows and water-side pressure requirements.
  • Voltage, phase, frequency, starting method and plant-room access / lifting constraints.
  • Equipment schedule or BOQ, project location, destination country and requested delivery date.

Application suitability requires a review of the project requirements and selected model.

Project equipment procurement

Delta M&E reviews equipment requirements, manufacturer selections and supply arrangements for each inquiry. Send your BOQ or equipment schedule to discuss the required model, documentation and destination.

TCL CSOT India — historical Hitachi centrifugal chiller supply. The project record does not identify one of the series listed here.

Technical documents

No model-specific technical documents are available for download on this page. Request Technical Information

Related series

REQUEST A QUOTE / TECHNICAL INFORMATION

Prepare your equipment requirements

Product reference: Hitachi VG Direct-Drive Inverter Centrifugal Chillers

Prepare your BOQ or model list, quantity, project location, design conditions and power supply. For stock inquiries, confirm the exact model, condition, export suitability and delivery requirements.

Request a Quote

Email your requirements to [email protected]. You can include your BOQ or equipment schedule. See what to include in your inquiry.