Hitachi Cooling & Heating · Series overview
Hitachi G Series
Air-Cooled Scroll Chiller / Heat Pump
Hitachi Cooling & Heating / SERIES OVERVIEW
R32 modular inverter air-source heat pump

RMVS uses DC-inverter enhanced-vapour-injection scroll compressors in an air-to-water arrangement. PH and MH references have separate cooling and heating ratings, seasonal indices and hydraulic data. NMW and AMW selections also differ in guards and weight. The tables describe individual modules, so a combined installation needs a separate equipment and water-system selection.
Match the complete model and configuration to your design duty. Compare ratings only at the stated water and ambient conditions; then send the model reference, quantity and project requirements for review.
Scroll each table horizontally to compare all columns. Model references remain visible as you scroll.
R32 modular air-source heat pump; single-module ratings.
| Model reference | Cooling capacity(kW) | Cooling input(kW) | EER(kW/kW) | Heating capacity(kW) | Heating input(kW) | Heating COP(kW/kW) | IPLV (C)(kW/kW) | CSPF((kW·h)/(kW·h)) |
|---|---|---|---|---|---|---|---|---|
| RMVS065PHFNMWRequest a Quote | 65 | 20.96 | 3.1 | 70 | 20.89 | 3.35 | 4.75 | 5 |
| RMVS065PHFAMWRequest a Quote | 65 | 20.96 | 3.1 | 70 | 20.89 | 3.35 | 4.75 | 5 |
| RMVS140PHFNMWRequest a Quote | 140 | 44.58 | 3.14 | 145 | 44.61 | 3.25 | 4.6 | 4.7 |
| RMVS140PHFAMWRequest a Quote | 140 | 44.58 | 3.14 | 145 | 44.61 | 3.25 | 4.6 | 4.7 |
R32 modular air-source heat pump; single-module ratings.
| Model reference | Power supply | Refrigerant | Net weight(kg) | Operating weight(kg) | H × W × D (mm) | Refrigerant charge (kg × circuits) | Compressors(count) | Fans(count) | Fan input (kW × fans) | Rated water flow(m³/h) | Water connection | Water pressure drop incl. filter(kPa) | Air-side guard |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RMVS065PHFNMWRequest a Quote | 380–415 V / 3N~ / 50 Hz | R32 | 337 | 345 | 1795×1600×765 | 12.0×1 | 1 | 2 | 0.75×2 | 11.18 | G2 inch male thread | 30 | Not fitted in table |
| RMVS065PHFAMWRequest a Quote | 380–415 V / 3N~ / 50 Hz | R32 | 342 | 350 | 1795×1600×765 | 12.0×1 | 1 | 2 | 0.75×2 | 11.18 | G2 inch male thread | 30 | Standard guard |
| RMVS140PHFNMWRequest a Quote | 380–415 V / 3N~ / 50 Hz | R32 | 690 | 706 | 1818×3298×816 | 12.5×2 | 2 | 4 | 0.75×4 | 24.08 | DN65 grooved | 30 | Not fitted in table |
| RMVS140PHFAMWRequest a Quote | 380–415 V / 3N~ / 50 Hz | R32 | 697 | 713 | 1818×3298×816 | 12.5×2 | 2 | 4 | 0.75×4 | 24.08 | DN65 grooved | 30 | Standard guard |
R32 modular air-source heat pump; single-module ratings.
| Model reference | Maximum current(A) | Cooling current(A) | Heating current(A) | Cooling / heating sound pressure (dB(A)) |
|---|---|---|---|---|
| RMVS065PHFNMWRequest a Quote | 48.5 | 34.65 | 34.5 | 69.0/70.0 |
| RMVS065PHFAMWRequest a Quote | 48.5 | 34.65 | 34.5 | 69.0/70.0 |
| RMVS140PHFNMWRequest a Quote | 97 | 73.62 | 73.68 | 69.0/70.5 |
| RMVS140PHFAMWRequest a Quote | 97 | 73.62 | 73.68 | 69.0/70.5 |
R32 modular air-source heat pump; single-module ratings.
| Model reference | Cooling capacity(kW) | Cooling input(kW) | EER(kW/kW) | Heating capacity(kW) | Heating input(kW) | Heating COP(kW/kW) | IPLV (C)(kW/kW) | CSPF((kW·h)/(kW·h)) |
|---|---|---|---|---|---|---|---|---|
| RMVS065MHFNMWRequest a Quote | 66 | 21.56 | 3.06 | 68 | 20.6 | 3.3 | 4.05 | 4.55 |
| RMVS065MHFAMWRequest a Quote | 66 | 21.56 | 3.06 | 68 | 20.6 | 3.3 | 4.05 | 4.55 |
| RMVS130MHFNMWRequest a Quote | 130 | 43.33 | 3 | 137 | 41.51 | 3.3 | 4.05 | 4.55 |
| RMVS130MHFAMWRequest a Quote | 130 | 43.33 | 3 | 137 | 41.51 | 3.3 | 4.05 | 4.55 |
R32 modular air-source heat pump; single-module ratings.
| Model reference | Power supply | Refrigerant | Net weight(kg) | Operating weight(kg) | H × W × D (mm) | Refrigerant charge (kg × circuits) | Compressors(count) | Fans(count) | Fan input (kW × fans) | Rated water flow(m³/h) | Water connection | Water pressure drop incl. filter(kPa) | Air-side guard |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RMVS065MHFNMWRequest a Quote | 380–415 V / 3N~ / 50 Hz | R32 | 321 | 327 | 1795×1600×765 | 12.0×1 | 1 | 2 | 0.75×2 | 11.35 | G2 inch male thread | 40 | Not fitted in table |
| RMVS065MHFAMWRequest a Quote | 380–415 V / 3N~ / 50 Hz | R32 | 326 | 332 | 1795×1600×765 | 12.0×1 | 1 | 2 | 0.75×2 | 11.35 | G2 inch male thread | 40 | Standard guard |
| RMVS130MHFNMWRequest a Quote | 380–415 V / 3N~ / 50 Hz | R32 | 680 | 692 | 1818×3298×816 | 12.0×2 | 2 | 4 | 0.75×4 | 22.36 | DN65 grooved | 32 | Not fitted in table |
| RMVS130MHFAMWRequest a Quote | 380–415 V / 3N~ / 50 Hz | R32 | 688 | 700 | 1818×3298×816 | 12.0×2 | 2 | 4 | 0.75×4 | 22.36 | DN65 grooved | 32 | Standard guard |
R32 modular air-source heat pump; single-module ratings.
| Model reference | Maximum current(A) | Cooling current(A) | Heating current(A) | Cooling / heating sound pressure (dB(A)) |
|---|---|---|---|---|
| RMVS065MHFNMWRequest a Quote | 48.5 | 35.61 | 34.02 | 67.0/68.5 |
| RMVS065MHFAMWRequest a Quote | 48.5 | 35.61 | 34.02 | 67.0/68.5 |
| RMVS130MHFNMWRequest a Quote | 97 | 71.56 | 68.55 | 68.0/69.5 |
| RMVS130MHFAMWRequest a Quote | 97 | 71.56 | 68.55 | 68.0/69.5 |
Application suitability requires a review of the project requirements and selected model.
Delta M&E reviews equipment requirements, manufacturer selections and supply arrangements for each inquiry. Send your BOQ or equipment schedule to discuss the required model, documentation and destination.
No model-specific technical documents are available for download on this page. Request Technical Information

Hitachi Cooling & Heating · Series overview
Air-Cooled Scroll Chiller / Heat Pump

Hitachi Cooling & Heating · Series overview
Water / ground-source twin-screw heat pump

Hitachi Cooling & Heating · Series overview
R32 low-ambient inverter air-source heat pump
REQUEST A QUOTE / TECHNICAL INFORMATION
Product reference: Hitachi RMVS Modular Air-Source Heat Pumps
Prepare your BOQ or model list, quantity, project location, design conditions and power supply. For stock inquiries, confirm the exact model, condition, export suitability and delivery requirements.
Request a QuoteEmail your requirements to [email protected]. You can include your BOQ or equipment schedule. See what to include in your inquiry.