Hitachi Cooling & Heating / SERIES OVERVIEW

Hitachi RMVS Modular Air-Source Heat Pumps

R32 modular inverter air-source heat pump

Brand
Hitachi Cooling & Heating
Series
RMVS PH / MH
Equipment category
Heat Pumps
Hitachi RMVS modular air-source heat pump configuration
Representative image. Appearance may vary by configuration.

Product overview

RMVS uses DC-inverter enhanced-vapour-injection scroll compressors in an air-to-water arrangement. PH and MH references have separate cooling and heating ratings, seasonal indices and hydraulic data. NMW and AMW selections also differ in guards and weight. The tables describe individual modules, so a combined installation needs a separate equipment and water-system selection.

Key technical specifications

Match the complete model and configuration to your design duty. Compare ratings only at the stated water and ambient conditions; then send the model reference, quantity and project requirements for review.

Scroll each table horizontally to compare all columns. Model references remain visible as you scroll.

RMVS-PH — performance

R32 modular air-source heat pump; single-module ratings.

RMVS-PH — performance. R32 modular air-source heat pump; single-module ratings.
Model referenceCooling capacity(kW)Cooling input(kW)EER(kW/kW)Heating capacity(kW)Heating input(kW)Heating COP(kW/kW)IPLV (C)(kW/kW)CSPF((kW·h)/(kW·h))
RMVS065PHFNMWRequest a Quote6520.963.17020.893.354.755
RMVS065PHFAMWRequest a Quote6520.963.17020.893.354.755
RMVS140PHFNMWRequest a Quote14044.583.1414544.613.254.64.7
RMVS140PHFAMWRequest a Quote14044.583.1414544.613.254.64.7
  • Cooling: leaving water 7 °C, water-flow coefficient 0.172 m³/(h·kW), outdoor air 35 °C. Heating: leaving water 45 °C, same flow coefficient, outdoor dry bulb / wet bulb 7 / 6 °C.
  • DC-inverter enhanced-vapour-injection scroll compressors. Brazed-plate water heat exchanger. Water pressure drop includes the supplied Y-strainer.
  • Sound pressure is measured in a semi-anechoic room; values are not a project-site sound guarantee. NMW and AMW guard / weight configurations remain separate.
  • Manufacturer reference: JCH-RMVS-PH(MH)-250603 / FY26 20260318; physical PDF page 14.

RMVS-PH — installation

R32 modular air-source heat pump; single-module ratings.

RMVS-PH — installation. R32 modular air-source heat pump; single-module ratings.
Model referencePower supplyRefrigerantNet weight(kg)Operating weight(kg)H × W × D (mm)Refrigerant charge (kg × circuits)Compressors(count)Fans(count)Fan input (kW × fans)Rated water flow(m³/h)Water connectionWater pressure drop incl. filter(kPa)Air-side guard
RMVS065PHFNMWRequest a Quote380–415 V / 3N~ / 50 HzR323373451795×1600×76512.0×1120.75×211.18G2 inch male thread30Not fitted in table
RMVS065PHFAMWRequest a Quote380–415 V / 3N~ / 50 HzR323423501795×1600×76512.0×1120.75×211.18G2 inch male thread30Standard guard
RMVS140PHFNMWRequest a Quote380–415 V / 3N~ / 50 HzR326907061818×3298×81612.5×2240.75×424.08DN65 grooved30Not fitted in table
RMVS140PHFAMWRequest a Quote380–415 V / 3N~ / 50 HzR326977131818×3298×81612.5×2240.75×424.08DN65 grooved30Standard guard
  • Cooling: leaving water 7 °C, water-flow coefficient 0.172 m³/(h·kW), outdoor air 35 °C. Heating: leaving water 45 °C, same flow coefficient, outdoor dry bulb / wet bulb 7 / 6 °C.
  • DC-inverter enhanced-vapour-injection scroll compressors. Brazed-plate water heat exchanger. Water pressure drop includes the supplied Y-strainer.
  • Sound pressure is measured in a semi-anechoic room; values are not a project-site sound guarantee. NMW and AMW guard / weight configurations remain separate.
  • Manufacturer reference: JCH-RMVS-PH(MH)-250603 / FY26 20260318; physical PDF page 14.

RMVS-PH — electrical

R32 modular air-source heat pump; single-module ratings.

RMVS-PH — electrical. R32 modular air-source heat pump; single-module ratings.
Model referenceMaximum current(A)Cooling current(A)Heating current(A)Cooling / heating sound pressure (dB(A))
RMVS065PHFNMWRequest a Quote48.534.6534.569.0/70.0
RMVS065PHFAMWRequest a Quote48.534.6534.569.0/70.0
RMVS140PHFNMWRequest a Quote9773.6273.6869.0/70.5
RMVS140PHFAMWRequest a Quote9773.6273.6869.0/70.5
  • Cooling: leaving water 7 °C, water-flow coefficient 0.172 m³/(h·kW), outdoor air 35 °C. Heating: leaving water 45 °C, same flow coefficient, outdoor dry bulb / wet bulb 7 / 6 °C.
  • DC-inverter enhanced-vapour-injection scroll compressors. Brazed-plate water heat exchanger. Water pressure drop includes the supplied Y-strainer.
  • Sound pressure is measured in a semi-anechoic room; values are not a project-site sound guarantee. NMW and AMW guard / weight configurations remain separate.
  • Manufacturer reference: JCH-RMVS-PH(MH)-250603 / FY26 20260318; physical PDF page 14.

RMVS-MH — performance

R32 modular air-source heat pump; single-module ratings.

RMVS-MH — performance. R32 modular air-source heat pump; single-module ratings.
Model referenceCooling capacity(kW)Cooling input(kW)EER(kW/kW)Heating capacity(kW)Heating input(kW)Heating COP(kW/kW)IPLV (C)(kW/kW)CSPF((kW·h)/(kW·h))
RMVS065MHFNMWRequest a Quote6621.563.066820.63.34.054.55
RMVS065MHFAMWRequest a Quote6621.563.066820.63.34.054.55
RMVS130MHFNMWRequest a Quote13043.33313741.513.34.054.55
RMVS130MHFAMWRequest a Quote13043.33313741.513.34.054.55
  • Cooling: leaving water 7 °C, water-flow coefficient 0.172 m³/(h·kW), outdoor air 35 °C. Heating: leaving water 45 °C, same flow coefficient, outdoor dry bulb / wet bulb 7 / 6 °C.
  • DC-inverter enhanced-vapour-injection scroll compressors. Brazed-plate water heat exchanger. Water pressure drop includes the supplied Y-strainer.
  • Sound pressure is measured in a semi-anechoic room; values are not a project-site sound guarantee. NMW and AMW guard / weight configurations remain separate.
  • Manufacturer reference: JCH-RMVS-PH(MH)-250603 / FY26 20260318; physical PDF page 14.

RMVS-MH — installation

R32 modular air-source heat pump; single-module ratings.

RMVS-MH — installation. R32 modular air-source heat pump; single-module ratings.
Model referencePower supplyRefrigerantNet weight(kg)Operating weight(kg)H × W × D (mm)Refrigerant charge (kg × circuits)Compressors(count)Fans(count)Fan input (kW × fans)Rated water flow(m³/h)Water connectionWater pressure drop incl. filter(kPa)Air-side guard
RMVS065MHFNMWRequest a Quote380–415 V / 3N~ / 50 HzR323213271795×1600×76512.0×1120.75×211.35G2 inch male thread40Not fitted in table
RMVS065MHFAMWRequest a Quote380–415 V / 3N~ / 50 HzR323263321795×1600×76512.0×1120.75×211.35G2 inch male thread40Standard guard
RMVS130MHFNMWRequest a Quote380–415 V / 3N~ / 50 HzR326806921818×3298×81612.0×2240.75×422.36DN65 grooved32Not fitted in table
RMVS130MHFAMWRequest a Quote380–415 V / 3N~ / 50 HzR326887001818×3298×81612.0×2240.75×422.36DN65 grooved32Standard guard
  • Cooling: leaving water 7 °C, water-flow coefficient 0.172 m³/(h·kW), outdoor air 35 °C. Heating: leaving water 45 °C, same flow coefficient, outdoor dry bulb / wet bulb 7 / 6 °C.
  • DC-inverter enhanced-vapour-injection scroll compressors. Brazed-plate water heat exchanger. Water pressure drop includes the supplied Y-strainer.
  • Sound pressure is measured in a semi-anechoic room; values are not a project-site sound guarantee. NMW and AMW guard / weight configurations remain separate.
  • Manufacturer reference: JCH-RMVS-PH(MH)-250603 / FY26 20260318; physical PDF page 14.

RMVS-MH — electrical

R32 modular air-source heat pump; single-module ratings.

RMVS-MH — electrical. R32 modular air-source heat pump; single-module ratings.
Model referenceMaximum current(A)Cooling current(A)Heating current(A)Cooling / heating sound pressure (dB(A))
RMVS065MHFNMWRequest a Quote48.535.6134.0267.0/68.5
RMVS065MHFAMWRequest a Quote48.535.6134.0267.0/68.5
RMVS130MHFNMWRequest a Quote9771.5668.5568.0/69.5
RMVS130MHFAMWRequest a Quote9771.5668.5568.0/69.5
  • Cooling: leaving water 7 °C, water-flow coefficient 0.172 m³/(h·kW), outdoor air 35 °C. Heating: leaving water 45 °C, same flow coefficient, outdoor dry bulb / wet bulb 7 / 6 °C.
  • DC-inverter enhanced-vapour-injection scroll compressors. Brazed-plate water heat exchanger. Water pressure drop includes the supplied Y-strainer.
  • Sound pressure is measured in a semi-anechoic room; values are not a project-site sound guarantee. NMW and AMW guard / weight configurations remain separate.
  • Manufacturer reference: JCH-RMVS-PH(MH)-250603 / FY26 20260318; physical PDF page 14.

Key configuration options

  • PH and MH are kept in separate tables; RMVS065MH cooling is 66 kW in this brochure, while RMVS065PH cooling is 65 kW.
  • 380–415 V / 3N~ / 50 Hz; R32; brazed-plate water heat exchanger. The water pressure drop includes the supplied Y-strainer.
  • AMW references include the listed air-side guard; NMW and AMW net / operating weights remain distinct.
  • Operating envelopes vary with leaving-water temperature. Selection outside the plotted standard range requires manufacturer review.

Applications

  • Commercial air-to-water heating and chilled-water equipment procurement.
  • Projects evaluating multiple modules against the required water temperatures, electrical supply and load profile.

Information for equipment selection

  • Complete RMVS PH / MH reference, NMW / AMW configuration and module quantity.
  • Cooling / heating loads, design ambient conditions, water temperatures, flow and control requirements.
  • Power supply, location, acoustic constraints and destination country.

Application suitability requires a review of the project requirements and selected model.

Project equipment procurement

Delta M&E reviews equipment requirements, manufacturer selections and supply arrangements for each inquiry. Send your BOQ or equipment schedule to discuss the required model, documentation and destination.

Technical documents

No model-specific technical documents are available for download on this page. Request Technical Information

Related series

REQUEST A QUOTE / TECHNICAL INFORMATION

Prepare your equipment requirements

Product reference: Hitachi RMVS Modular Air-Source Heat Pumps

Prepare your BOQ or model list, quantity, project location, design conditions and power supply. For stock inquiries, confirm the exact model, condition, export suitability and delivery requirements.

Request a Quote

Email your requirements to [email protected]. You can include your BOQ or equipment schedule. See what to include in your inquiry.