Hitachi Cooling & Heating / SERIES OVERVIEW

Hitachi AZ1 / AZP1 Air-Cooled Screw Chillers & Heat Pumps

Air-cooled screw chiller / heat pump

Brand
Hitachi Cooling & Heating
Series
AZ1 / AZP1
Equipment category
Chillers

Product overview

AZ1 and AZP1 are air-cooled screw equipment families with separate RCUF cooling-only and RHUF heat-pump selections. AZ1 has 18 listed sizes and AZP1 has 17, with model-specific differences in duty, circuit arrangement, dimensions and weight. Compare the four tables at their stated cooling or heating conditions. A shared size code does not establish the same cooling output for a chiller and its heat-pump variant.

Key technical specifications

Match the complete model and configuration to your design duty. Compare ratings only at the stated water and ambient conditions; then send the model reference, quantity and project requirements for review.

Scroll each table horizontally to compare all columns. Model references remain visible as you scroll.

AZ1 / RCUF — cooling-only performance

Semi-hermetic twin-screw, fixed-speed air-cooled chillers.

AZ1 / RCUF — cooling-only performance. Semi-hermetic twin-screw, fixed-speed air-cooled chillers.
Model referenceCooling capacity(kW)Cooling capacity (source)(RT)Cooling input power(kW)Cooling COP(W/W)Cooling rated current by circuit (A)Cooling maximum current by circuit (A)
RCUF45AZ1Request a Quote1584549.73.1891137
RCUF50AZ1Request a Quote17550553.18101151
RCUF60AZ1Request a Quote2156167.63.18123185
RCUF90AZ1Request a Quote3169099.43.18183274
RCUF100AZ1Request a Quote350100110.13.18202303
RCUF120AZ1Request a Quote430122135.23.18247370
RCUF150AZ1Request a Quote525149165.13.18303454
RCUF180AZ1Request a Quote645183202.83.18370555
RCUF200AZ1Request a Quote700199220.23.18202/202303/303
RCUF220AZ1Request a Quote780222245.33.18245/204367/306
RCUF240AZ1Request a Quote860245270.43.18247/247370/370
RCUF270AZ1Request a Quote955272300.33.18305/244458/366
RCUF300AZ1Request a Quote1050299330.23.18303/303454/454
RCUF330AZ1Request a Quote1170333367.93.18367/306551/459
RCUF360AZ1Request a Quote1290367405.73.18370/370555/555
RCUF400AZ1Request a Quote1400398440.33.18303/303/202454/454/303
RCUF420AZ1Request a Quote1480421465.43.18304/304/227457/457/341
RCUF450AZ1Request a Quote1575448495.33.18303/303/303454/454/454
  • Cooling: leaving water 7 °C; water flow 0.172 m³/(h·kW); outdoor air 35 °C dry bulb. Water-side fouling factor: 0.018 m²·°C/kW.
  • R134a; main supply 380 V / 3 phase / 50 Hz; control supply 220 V / 1 phase / 50 Hz. Project duty, ambient conditions, electrical arrangements and water-side design pressure need a final equipment selection.
  • Full model references combine only the printed RCUF prefix, listed size and AZ1 suffix. RCUF and RHUF ratings are independent.
  • Cooling envelope: leaving water 5–15 °C; outdoor air 5–43 °C.
  • Source: AZ1 / AZP1 brochure, print code Z0050004-260914.

AZ1 / RCUF — water-side and installation data

Parentheses retain the source section weights; slash-separated pressure drops identify the printed circuit values, not totals.

AZ1 / RCUF — water-side and installation data. Parentheses retain the source section weights; slash-separated pressure drops identify the printed circuit values, not totals.
Model referenceEvaporator water flow(m³/h)Evaporator pressure drop by circuit (kPa)Water connectionFan quantity(units)Total fan input(kW)Total airflow(m³/min)Length(mm)Width(mm)Height(mm)Net weight / section weights (kg)Operating weight / section weights (kg)
RCUF45AZ1Request a Quote27.234DN8044.49202390206021201,7501,880
RCUF50AZ1Request a Quote30.140DN8044.49202390206021201,7801,890
RCUF60AZ1Request a Quote3755DN8044.49202390206021201,8902,000
RCUF90AZ1Request a Quote54.440DN12588.818404490206021603,2503,400
RCUF100AZ1Request a Quote60.246DN12588.818404490206021603,3503,510
RCUF120AZ1Request a Quote7446DN12588.818404490206021603,5003,770
RCUF150AZ1Request a Quote90.346DN1251213.227606590206022004,9355,140
RCUF180AZ1Request a Quote110.960DN1251213.227606590206022006700 5,2007020 5,380
RCUF200AZ1Request a Quote120.446/46DN1251617.636809080206021606,700 (3350+3350)7,020 (3510+3510)
RCUF220AZ1Request a Quote134.246/46DN1251617.636809080206021606,850 (3500+3350)7,280 (3770+3510)
RCUF240AZ1Request a Quote147.946/46DN1251617.636809080206021607,000 (3500+3500)7,540 (3770+3770)
RCUF270AZ1Request a Quote164.346/46DN1252022460011180206022008,435 (4935+3500)8,910 (5140+3770)
RCUF300AZ1Request a Quote180.646/46DN1252426.4552013280206022009,870 (4935+4935)10,280 (5140+5140)
RCUF330AZ1Request a Quote201.260/46DN1252426.45520132802060220010,135 (5200+4935)10,520 (5380+5140)
RCUF360AZ1Request a Quote221.960/60DN1252426.45520132802060220010,400 (5200+5200)10,760 (5380+5380)
RCUF400AZ1Request a Quote240.846/46/46DN1253235.27360186702060220013,220 (4935+4935+3350)13,790 (5140+5140+3510)
RCUF420AZ1Request a Quote254.646/46/46DN1253235.27360186702060220013,370 (4935+4935+3500)14,050 (5140+5140+3770)
RCUF450AZ1Request a Quote270.946/46/46DN1253639.68280207702060220014,805 (4935+4935+4935)15,420 (5140+5140+5140)
  • Cooling: leaving water 7 °C; water flow 0.172 m³/(h·kW); outdoor air 35 °C dry bulb. Water-side fouling factor: 0.018 m²·°C/kW.
  • R134a; main supply 380 V / 3 phase / 50 Hz; control supply 220 V / 1 phase / 50 Hz. Project duty, ambient conditions, electrical arrangements and water-side design pressure need a final equipment selection.
  • Full model references combine only the printed RCUF prefix, listed size and AZ1 suffix. RCUF and RHUF ratings are independent.
  • Cooling envelope: leaving water 5–15 °C; outdoor air 5–43 °C.
  • Source: AZ1 / AZP1 brochure, print code Z0050004-260914.

AZ1 / RHUF — cooling and heating performance

Semi-hermetic twin-screw, fixed-speed air-cooled heat pumps.

AZ1 / RHUF — cooling and heating performance. Semi-hermetic twin-screw, fixed-speed air-cooled heat pumps.
Model referenceCooling capacity(kW)Cooling capacity (source)(RT)Cooling input power(kW)Cooling COP(W/W)Heating capacity(kW)Heating capacity (source)(RT)Heating input power(kW)Cooling rated current by circuit (A)Cooling maximum current by circuit (A)
RHUF45AZ1Request a Quote1584549.73.181584549.491137
RHUF50AZ1Request a Quote17550553.181785155.6101151
RHUF60AZ1Request a Quote2055867.23.052005762.5123184
RHUF90AZ1Request a Quote3169099.43.183169098.8183274
RHUF100AZ1Request a Quote3501001103.18356101111.3202303
RHUF120AZ1Request a Quote410117134.43.05400114125245368
RHUF150AZ1Request a Quote5251491653.18534152166.9303454
RHUF180AZ1Request a Quote615175201.63.05600171187.5368552
RHUF200AZ1Request a Quote7001992203.18712202222.5202/202303/303
RHUF220AZ1Request a Quote760216244.23.11756215236.3244/203365/305
RHUF240AZ1Request a Quote820233268.83.05800228250245/245368/368
RHUF270AZ1Request a Quote935266299.53.12934266291.9305/244457/365
RHUF300AZ1Request a Quote10502993303.181068304333.8303/303454/454
RHUF330AZ1Request a Quote1140324366.73.111134323354.4366/305549/457
RHUF360AZ1Request a Quote1230350403.23.051200341375368/368552/552
RHUF400AZ1Request a Quote14003984403.181424405445303/303/202454/454/303
RHUF420AZ1Request a Quote1460415464.43.141468417458.8304/304/227456/456/340
RHUF450AZ1Request a Quote15754484953.181602456500.7303/303/303454/454/454
  • Cooling: leaving water 7 °C; water flow 0.172 m³/(h·kW); outdoor air 35 °C dry bulb. Water-side fouling factor: 0.018 m²·°C/kW.
  • R134a; main supply 380 V / 3 phase / 50 Hz; control supply 220 V / 1 phase / 50 Hz. Project duty, ambient conditions, electrical arrangements and water-side design pressure need a final equipment selection.
  • Heating: leaving water 45 °C; water flow 0.172 m³/(h·kW); outdoor air 7 °C dry bulb / 6 °C wet bulb. These are separate heating ratings, not an extension of the cooling test point.
  • Full model references combine only the printed RHUF prefix, listed size and AZ1 suffix. RCUF and RHUF ratings are independent.
  • Cooling envelope: leaving water 5–15 °C; outdoor air 10–43 °C. Heating: leaving water 35–60 °C; outdoor air −9.5–21 °C dry bulb / −10–15.5 °C wet bulb; duty below −10 °C requires a manufacturer selection.
  • Source: AZ1 / AZP1 brochure, print code Z0050004-260914.

AZ1 / RHUF — water-side and installation data

Parentheses retain the source section weights; slash-separated pressure drops identify the printed circuit values, not totals.

AZ1 / RHUF — water-side and installation data. Parentheses retain the source section weights; slash-separated pressure drops identify the printed circuit values, not totals.
Model referenceEvaporator water flow(m³/h)Evaporator pressure drop by circuit (kPa)Water connectionFan quantity(units)Total fan input(kW)Total airflow(m³/min)Length(mm)Width(mm)Height(mm)Net weight / section weights (kg)Operating weight / section weights (kg)
RHUF45AZ1Request a Quote27.234DN8044.49202390206021201,8701,990
RHUF50AZ1Request a Quote30.140DN8044.49202390206021201,9202,030
RHUF60AZ1Request a Quote35.355DN8044.49202390206021202,0202,110
RHUF90AZ1Request a Quote54.440DN12588.818404490206021603,9004,080
RHUF100AZ1Request a Quote60.246DN12588.818404490206021603,9404,100
RHUF120AZ1Request a Quote70.546DN12588.818404490206021604,0004,190
RHUF150AZ1Request a Quote90.355DN1251213.227606590206022005,9006,170
RHUF180AZ1Request a Quote105.860DN1251213.227606590206022007800 5,9808200 6,250
RHUF200AZ1Request a Quote120.446/46DN1251617.63680908020602160Pending confirmation8,200 (4100+4100)
RHUF220AZ1Request a Quote130.746/46DN1251617.636809080206021607,940 (4000+3940)8,290 (4190+4100)
RHUF240AZ1Request a Quote14146/46DN1251617.636809080206021608,000 (4000+4000)8,380 (4190+4190)
RHUF270AZ1Request a Quote160.855/46DN1252022460011180206022009,900 (5900+4000)10,360 (6170+4190)
RHUF300AZ1Request a Quote180.655/55DN1252426.45520132802060220011,800 (5900+5900)12,340 (6170+6170)
RHUF330AZ1Request a Quote196.160/55DN1252426.45520132802060220011,880 (5980+5900)12,420 (6250+6170)
RHUF360AZ1Request a Quote211.660/60DN1252426.45520132802060220011,960 (5980+5980)12,500 (6250+6250)
RHUF400AZ1Request a Quote240.855/55/46DN1253235.27360186702060220015,740 (5900+5900+3940)16,440 (6170+6170+4100)
RHUF420AZ1Request a Quote251.155/55/46DN1253235.27360186702060220015,800 (5900+5900+4000)16,530 (6170+6170+4190)
RHUF450AZ1Request a Quote270.955/55/55DN1253639.68280207702060220017,700 (5900+5900+5900)18,510 (6170+6170+6170)
  • Cooling: leaving water 7 °C; water flow 0.172 m³/(h·kW); outdoor air 35 °C dry bulb. Water-side fouling factor: 0.018 m²·°C/kW.
  • R134a; main supply 380 V / 3 phase / 50 Hz; control supply 220 V / 1 phase / 50 Hz. Project duty, ambient conditions, electrical arrangements and water-side design pressure need a final equipment selection.
  • Heating: leaving water 45 °C; water flow 0.172 m³/(h·kW); outdoor air 7 °C dry bulb / 6 °C wet bulb. These are separate heating ratings, not an extension of the cooling test point.
  • Full model references combine only the printed RHUF prefix, listed size and AZ1 suffix. RCUF and RHUF ratings are independent.
  • Cooling envelope: leaving water 5–15 °C; outdoor air 10–43 °C. Heating: leaving water 35–60 °C; outdoor air −9.5–21 °C dry bulb / −10–15.5 °C wet bulb; duty below −10 °C requires a manufacturer selection.
  • Source: AZ1 / AZP1 brochure, print code Z0050004-260914.
  • Net weight for RHUF200AZ1 requires manufacturer confirmation; no net-weight value is assigned here.

AZP1 / RCUF — cooling-only performance

Semi-hermetic twin-screw, fixed-speed air-cooled chillers.

AZP1 / RCUF — cooling-only performance. Semi-hermetic twin-screw, fixed-speed air-cooled chillers.
Model referenceCooling capacity(kW)Cooling capacity (source)(RT)Cooling input power(kW)Cooling COP(W/W)Cooling rated current by circuit (A)Cooling maximum current by circuit (A)
RCUF45AZP1Request a Quote1604647.33.3887131
RCUF50AZP1Request a Quote1785152.73.3897145
RCUF60AZP1Request a Quote2156163.63.38117176
RCUF90AZP1Request a Quote3209194.73.38174262
RCUF100AZP1Request a Quote356101105.33.38193290
RCUF120AZP1Request a Quote430122127.23.38235352
RCUF150AZP1Request a Quote5341521583.38290435
RCUF180AZP1Request a Quote640182189.43.38174/174262/262
RCUF200AZP1Request a Quote712202210.63.38193/193290/290
RCUF240AZP1Request a Quote860245254.43.38235/235352/352
RCUF270AZP1Request a Quote964274285.23.38292/233438/350
RCUF300AZP1Request a Quote10683043163.38290/290435/435
RCUF320AZP1Request a Quote1142325337.83.38233/194/194350/291/291
RCUF360AZP1Request a Quote1290367381.63.38235/235/235352/352/352
RCUF400AZP1Request a Quote1424405421.33.38290/290/193435/435/290
RCUF420AZP1Request a Quote1498426443.23.38291/291/233437/437/349
RCUF450AZP1Request a Quote16024564743.38290/290/290435/435/435
  • Cooling: leaving water 7 °C; water flow 0.172 m³/(h·kW); outdoor air 35 °C dry bulb. Water-side fouling factor: 0.018 m²·°C/kW.
  • R134a; main supply 380 V / 3 phase / 50 Hz; control supply 220 V / 1 phase / 50 Hz. Project duty, ambient conditions, electrical arrangements and water-side design pressure need a final equipment selection.
  • Full model references combine only the printed RCUF prefix, listed size and AZP1 suffix. RCUF and RHUF ratings are independent.
  • Cooling envelope: leaving water 5–15 °C; outdoor air 5–43 °C.
  • Source: AZ1 / AZP1 brochure, print code Z0050004-260914.

AZP1 / RCUF — water-side and installation data

Parentheses retain the source section weights; slash-separated pressure drops identify the printed circuit values, not totals.

AZP1 / RCUF — water-side and installation data. Parentheses retain the source section weights; slash-separated pressure drops identify the printed circuit values, not totals.
Model referenceEvaporator water flow(m³/h)Evaporator pressure drop by circuit (kPa)Water connectionFan quantity(units)Total fan input(kW)Total airflow(m³/min)Length(mm)Width(mm)Height(mm)Net weight / section weights (kg)Operating weight / section weights (kg)
RCUF45AZP1Request a Quote27.534DN8044.49202390206021201,8201,885
RCUF50AZP1Request a Quote30.640DN8044.49202390206021201,8451,935
RCUF60AZP1Request a Quote3755DN8066.613803300206021202,1802,310
RCUF90AZP1Request a Quote5540DN12588.818404490206021603,3403,490
RCUF100AZP1Request a Quote61.246DN12588.818404490206021603,4403,590
RCUF120AZP1Request a Quote7446DN1251213.227606310206022004,3004,580
RCUF150AZP1Request a Quote91.846DN1251213.227606590206022006680 5,0356980 5,285
RCUF180AZP1Request a Quote110.140/40DN1251617.636809080206021606,680 (3340+3340)6,980 (3490+3490)
RCUF200AZP1Request a Quote122.546/46DN1251617.636809080206021606,880 (3440+3440)7,180 (3590+3590)
RCUF240AZP1Request a Quote147.946/46DN1252426.4552012720206022008,600 (4300+4300)9,160 (4580+4580)
RCUF270AZP1Request a Quote165.846/46DN1252426.4552013000206022009,335 (5035+4300)9,865 (5285+4580)
RCUF300AZP1Request a Quote183.746/46DN1252426.45520132802060220010,070 (5035+5035)10,570 (5285+5285)
RCUF320AZP1Request a Quote196.446/46/46DN1252830.86440162902060220011,180 (4300+3440+3440)11,760 (4580+3590+3590)
RCUF360AZP1Request a Quote221.946/46/46DN1253639.68280199302060220012,900 (4300+4300+4300)13,740 (4580+4580+4580)
RCUF400AZP1Request a Quote244.946/46/46DN1253235.27360186702060220013,510 (5035+5035+3440)14,160 (5285+5285+3590)
RCUF420AZP1Request a Quote257.746/46/46DN1253639.68280204902060220014,370 (5035+5035+4300)15,150 (5285+5285+4580)
RCUF450AZP1Request a Quote275.546/46/46DN1253639.68280207702060220015,105 (5035+5035+5035)15,855 (5285+5285+5285)
  • Cooling: leaving water 7 °C; water flow 0.172 m³/(h·kW); outdoor air 35 °C dry bulb. Water-side fouling factor: 0.018 m²·°C/kW.
  • R134a; main supply 380 V / 3 phase / 50 Hz; control supply 220 V / 1 phase / 50 Hz. Project duty, ambient conditions, electrical arrangements and water-side design pressure need a final equipment selection.
  • Full model references combine only the printed RCUF prefix, listed size and AZP1 suffix. RCUF and RHUF ratings are independent.
  • Cooling envelope: leaving water 5–15 °C; outdoor air 5–43 °C.
  • Source: AZ1 / AZP1 brochure, print code Z0050004-260914.

AZP1 / RHUF — cooling and heating performance

Semi-hermetic twin-screw, fixed-speed air-cooled heat pumps.

AZP1 / RHUF — cooling and heating performance. Semi-hermetic twin-screw, fixed-speed air-cooled heat pumps.
Model referenceCooling capacity(kW)Cooling capacity (source)(RT)Cooling input power(kW)Cooling COP(W/W)Heating capacity(kW)Heating capacity (source)(RT)Heating input power(kW)Cooling rated current by circuit (A)Cooling maximum current by circuit (A)
RHUF45AZP1Request a Quote1604647.33.381624649.187131
RHUF50AZP1Request a Quote1785152.73.381805154.597145
RHUF60AZP1Request a Quote2106062.13.382106063.6115172
RHUF90AZP1Request a Quote3209194.73.383249298.2174262
RHUF100AZP1Request a Quote356101105.33.38360102109.1194290
RHUF120AZP1Request a Quote420119124.33.38420119127.3230345
RHUF150AZP1Request a Quote5341521583.38540154163.6290435
RHUF180AZP1Request a Quote640182189.43.38648184196.4174/174262/262
RHUF200AZP1Request a Quote712202210.63.38720205218.2193/193290/290
RHUF240AZP1Request a Quote840239248.63.38840239254.6230/230345/345
RHUF270AZP1Request a Quote954271282.33.38960273290.9289/231433/347
RHUF300AZP1Request a Quote10683043163.381080307327.2290/290435/435
RHUF320AZP1Request a Quote1132322334.93.381140324345.5231/193/193347/289/289
RHUF360AZP1Request a Quote1260358372.93.381260358381.9230/230/230345/345/345
RHUF400AZP1Request a Quote1424405421.33.381440410436.4290/290/193435/435/290
RHUF420AZP1Request a Quote1488423440.33.381500427454.5289/289/231434/434/347
RHUF450AZP1Request a Quote16024564743.381620461490.8290/290/290435/435/435
  • Cooling: leaving water 7 °C; water flow 0.172 m³/(h·kW); outdoor air 35 °C dry bulb. Water-side fouling factor: 0.018 m²·°C/kW.
  • R134a; main supply 380 V / 3 phase / 50 Hz; control supply 220 V / 1 phase / 50 Hz. Project duty, ambient conditions, electrical arrangements and water-side design pressure need a final equipment selection.
  • Heating: leaving water 45 °C; water flow 0.172 m³/(h·kW); outdoor air 7 °C dry bulb / 6 °C wet bulb. These are separate heating ratings, not an extension of the cooling test point.
  • Full model references combine only the printed RHUF prefix, listed size and AZP1 suffix. RCUF and RHUF ratings are independent.
  • Cooling envelope: leaving water 5–15 °C; outdoor air 10–43 °C. Heating: leaving water 35–60 °C; outdoor air −9.5–21 °C dry bulb / −10–15.5 °C wet bulb; duty below −10 °C requires a manufacturer selection.
  • Source: AZ1 / AZP1 brochure, print code Z0050004-260914.

AZP1 / RHUF — water-side and installation data

Parentheses retain the source section weights; slash-separated pressure drops identify the printed circuit values, not totals.

AZP1 / RHUF — water-side and installation data. Parentheses retain the source section weights; slash-separated pressure drops identify the printed circuit values, not totals.
Model referenceEvaporator water flow(m³/h)Evaporator pressure drop by circuit (kPa)Water connectionFan quantity(units)Total fan input(kW)Total airflow(m³/min)Length(mm)Width(mm)Height(mm)Net weight / section weights (kg)Operating weight / section weights (kg)
RHUF45AZP1Request a Quote27.534DN8044.49202390206021202,0652,165
RHUF50AZP1Request a Quote30.640DN8044.49202390206021202,1352,235
RHUF60AZP1Request a Quote36.155DN8066.613803300206021202,6802,810
RHUF90AZP1Request a Quote5540DN12588.818404490206021603,8804,030
RHUF100AZP1Request a Quote61.246DN12588.818404490206021604,0204,170
RHUF120AZP1Request a Quote72.246DN1251213.227606310206022004,8905,170
RHUF150AZP1Request a Quote91.846DN1251213.227606590206022007760 5,8058060 6,055
RHUF180AZP1Request a Quote110.140/40DN1251617.636809080206021607,760 (3880+3880)8,060 (4030+4030)
RHUF200AZP1Request a Quote122.546/46DN1251617.636809080206021608,040 (4020+4020)8,340 (4170+4170)
RHUF240AZP1Request a Quote144.546/46DN1252426.4552012720206022009,780 (4890+4890)10,340 (5170+5170)
RHUF270AZP1Request a Quote164.146/46DN1252426.45520130002060220010,695 (5805+4890)11,225 (6055+5170)
RHUF300AZP1Request a Quote183.746/46DN1252426.45520132802060220011,610 (5805+5805)12,110 (6055+6055)
RHUF320AZP1Request a Quote194.746/46/46DN1252830.86440162902060220012,930 (4890+4020+4020)13,510 (5170+4170+4170)
RHUF360AZP1Request a Quote216.746/46/46DN1253639.68280199302060220014,670 (4890+4890+4890)15,510 (5170+5170+5170)
RHUF400AZP1Request a Quote244.946/46/46DN1253235.27360186702060220015,630 (5805+5805+4020)16,280 (6055+6055+4170)
RHUF420AZP1Request a Quote255.946/46/46DN1253639.68280204902060220016,500 (5805+5805+4890)17,280 (6055+6055+5170)
RHUF450AZP1Request a Quote275.546/46/46DN1253639.68280207702060220017,415 (5805+5805+5805)18,165 (6055+6055+6055)
  • Cooling: leaving water 7 °C; water flow 0.172 m³/(h·kW); outdoor air 35 °C dry bulb. Water-side fouling factor: 0.018 m²·°C/kW.
  • R134a; main supply 380 V / 3 phase / 50 Hz; control supply 220 V / 1 phase / 50 Hz. Project duty, ambient conditions, electrical arrangements and water-side design pressure need a final equipment selection.
  • Heating: leaving water 45 °C; water flow 0.172 m³/(h·kW); outdoor air 7 °C dry bulb / 6 °C wet bulb. These are separate heating ratings, not an extension of the cooling test point.
  • Full model references combine only the printed RHUF prefix, listed size and AZP1 suffix. RCUF and RHUF ratings are independent.
  • Cooling envelope: leaving water 5–15 °C; outdoor air 10–43 °C. Heating: leaving water 35–60 °C; outdoor air −9.5–21 °C dry bulb / −10–15.5 °C wet bulb; duty below −10 °C requires a manufacturer selection.
  • Source: AZ1 / AZP1 brochure, print code Z0050004-260914.

Key configuration options

  • RCUF references provide cooling duty; RHUF references have separately stated cooling and heating ratings. Heating COP is not calculated where the table does not print it.
  • R134a, semi-hermetic twin-screw compressors. Multi-section unit arrangements retain their source circuit and section-weight notation.
  • Water connection, installation length and lifting / access requirements depend on the complete model and assembly.
  • Manufacturer reference: AZ1 / AZP1 brochure, print code Z0050004-260914. RHUF200AZ1 net weight awaits manufacturer clarification.

Applications

  • Outdoor chilled-water systems for commercial and industrial projects.
  • Cooling and, for the listed RHUF models, heating equipment selected for the project's design conditions.

Information for equipment selection

  • RCUF cooling-only or RHUF heat-pump duty, complete model reference and quantity.
  • Cooling and heating loads, water temperatures / flow and design outdoor dry-bulb / wet-bulb conditions.
  • Power supply, outdoor installation space, access and water-side design pressure.
  • Equipment schedule or BOQ, destination country and requested delivery date.

Application suitability requires a review of the project requirements and selected model.

Project equipment procurement

Delta M&E reviews equipment requirements, manufacturer selections and supply arrangements for each inquiry. Send your BOQ or equipment schedule to discuss the required model, documentation and destination.

Technical documents

No model-specific technical documents are available for download on this page. Request Technical Information

Related series

REQUEST A QUOTE / TECHNICAL INFORMATION

Prepare your equipment requirements

Product reference: Hitachi AZ1 / AZP1 Air-Cooled Screw Chillers & Heat Pumps

Prepare your BOQ or model list, quantity, project location, design conditions and power supply. For stock inquiries, confirm the exact model, condition, export suitability and delivery requirements.

Request a Quote

Email your requirements to [email protected]. You can include your BOQ or equipment schedule. See what to include in your inquiry.